Sweden (SE3) — Industrial Data Center Power & MW Credit Dossier
Stockholm / Mälardalen & Luleå Corridor · Svenska kraftnät (Bidding Zone SE3) · ECB EUR/USD 1.1130 (2026-10-29)
Grid Tariff & Clean-IP Telemetry (X_VAT)
- Jurisdiction & Bidding Zone
- Sweden (Nordics Hydro / SE3)
- Industrial Tariff (X_VAT)
- €0.0897 / kWh
- Authoritative Data Feed
- eurostat_nrg_pc_205
- Day-Ahead 24h Spot vs. Grid Adder
- Pro API (€149/mo) / €79 Pack
Project Finance & DSCR Underwriting Boundary
- Consumption Band
- 70–150 GWh/yr (8–17 MW Facility Load)
- Physics Load Curve
- 35% Baseline Idle + 65% Dynamic × PUE
- DLC vs. Air Thermal PUE
- 1.12 DLC · 1.38 Air
- Contracted DSCR Certification Gate
- Requires Verified FMV + Audited $/GPU-h
MW Facility Thermal Envelope: Direct Liquid Cooling (PUE 1.12) vs. Air (PUE 1.38)
Evaluated at 75% compute utilization (83.75% weighted IT power factor) in Sweden (SE3)| Colocation Capacity Tier | IT Nameplate (MW) | Active DLC Grid Draw (MW) | Active Air Grid Draw (MW) | Annual DLC Energy (MWh/yr) | 36m Power & Rack OpEx Split |
|---|---|---|---|---|---|
| 1.0 MW Edge / Enterprise Pod | 1.0 MW | 0.94 MW | 1.16 MW | 8,217 MWh | Pro API / €79 Pack |
| 5.0 MW Dedicated Colocation Hall | 5.0 MW | 4.69 MW | 5.78 MW | 41,084 MWh | Pro API / €79 Pack |
| 10.0 MW Institutional Compute Block | 10.0 MW | 9.38 MW | 11.56 MW | 82,169 MWh | Pro API / €79 Pack |
| 25.0 MW Hyperscale Powered Shell | 25.0 MW | 23.45 MW | 28.89 MW | 205,422 MWh | Pro API / €79 Pack |
8-Architecture 36-Month Net Own TCO & Credit Gate in Sweden (SE3)
Reference pod: 4 nodes · 18m age · 75% utilization · DLC PUE 1.12 · Tariff €0.0897/kWh (X_VAT)| Server Architecture (4 Nodes) | Active Load (kW) | 36m Net Own TCO (EUR) | Self-Hosted (€/GPU-h) | Borrowing-Base Gate | Monthly Debt & DSCR Series |
|---|---|---|---|---|---|
| H100 SXM5 (32 GPUs) | 38.27 kW | €829,648 | €1.32/h | INELIGIBLE_INSUFFICIENT_MARKET_EVIDENCE | Pro API / €79 Pack |
| H200 SXM5 (32 GPUs) | 39.40 kW | €760,109 | €1.21/h | INELIGIBLE_INSUFFICIENT_MARKET_EVIDENCE | Pro API / €79 Pack |
| B200 SXM6 (32 GPUs) | 54.03 kW | €1,065,003 | €1.69/h | INELIGIBLE_INSUFFICIENT_MARKET_EVIDENCE | Pro API / €79 Pack |
| H100 PCIe (32 GPUs) | 21.76 kW | €652,060 | €1.03/h | INELIGIBLE_INSUFFICIENT_MARKET_EVIDENCE | Pro API / €79 Pack |
| A100 80GB SXM4 (32 GPUs) | 24.39 kW | €397,194 | €0.63/h | INELIGIBLE_INSUFFICIENT_MARKET_EVIDENCE | Pro API / €79 Pack |
| L40S 48GB (32 GPUs) | 20.26 kW | €295,013 | €0.47/h | INELIGIBLE_INSUFFICIENT_MARKET_EVIDENCE | Pro API / €79 Pack |
| RTX PRO 6000 96GB (32 GPUs) | 25.51 kW | €247,906 | €0.39/h | INELIGIBLE_INSUFFICIENT_MARKET_EVIDENCE | Pro API / €79 Pack |
| RTX 5090 32GB (16 GPUs) | 11.63 kW | €79,390 | €0.25/h | INELIGIBLE_EULA_RESTRICTED | Pro API / €79 Pack |